Search the MySQL manual:

2.6.6.4 IBM-AIX notes

Automatic detection of xlC is missing from Autoconf, so a configure command something like this is needed when compiling MySQL (This example uses the IBM compiler):

export CC="xlc_r -ma -O3 -qstrict -qoptimize=3 -qmaxmem=8192 "
export CXX="xlC_r -ma -O3 -qstrict -qoptimize=3 -qmaxmem=8192"
export CFLAGS="-I /usr/local/include"
export LDFLAGS="-L /usr/local/lib"
export CPPFLAGS=$CFLAGS
export CXXFLAGS=$CFLAGS

./configure --prefix=/usr/local \
                --localstatedir=/var/mysql \
                --sysconfdir=/etc/mysql \
                --sbindir='/usr/local/bin' \
                --libexecdir='/usr/local/bin' \
                --enable-thread-safe-client \
                --enable-large-files

Above are the options used to compile the MySQL distribution that can be found at http://www-frec.bull.com/.

If you change the -O3 to -O2 in the above configure line, you must also remove the -qstrict option (this is a limitation in the IBM C compiler).

If you are using gcc or egcs to compile MySQL, you must use the -fno-exceptions flag, as the exception handling in gcc/egcs is not thread-safe! (This is tested with egcs 1.1.) There are also some known problems with IBM's assembler, which may cause it to generate bad code when used with gcc.

We recommend the following configure line with egcs and gcc 2.95 on AIX:

CC="gcc -pipe -mcpu=power -Wa,-many" \
CXX="gcc -pipe -mcpu=power -Wa,-many" \
CXXFLAGS="-felide-constructors -fno-exceptions -fno-rtti" \
./configure --prefix=/usr/local/mysql --with-low-memory

The -Wa,-many is necessary for the compile to be successful. IBM is aware of this problem but is in to hurry to fix it because of the workaround available. We don't know if the -fno-exceptions is required with gcc 2.95, but as MySQL doesn't use exceptions and the above option generates faster code, we recommend that you should always use this option with egcs / gcc.

If you get a problem with assembler code try changing the -mcpu=xxx to match your CPU. Typically power2, power, or powerpc may need to be used, alternatively you might need to use 604 or 604e. I'm not positive but I would think using "power" would likely be safe most of the time, even on a power2 machine.

If you don't know what your CPU is then do a "uname -m", this will give you back a string that looks like "000514676700", with a format of xxyyyyyymmss where xx and ss are always 0's, yyyyyy is a unique system id and mm is the id of the CPU Planar. A chart of these values can be found at http://publib.boulder.ibm.com/doc_link/en_US/a_doc_lib/cmds/aixcmds5/uname.htm. This will give you a machine type and a machine model you can use to determine what type of CPU you have.

If you have problems with signals (MySQL dies unexpectedly under high load) you may have found an OS bug with threads and signals. In this case you can tell MySQL not to use signals by configuring with:

shell> CFLAGS=-DDONT_USE_THR_ALARM CXX=gcc \
       CXXFLAGS="-felide-constructors -fno-exceptions -fno-rtti \
       -DDONT_USE_THR_ALARM" \
       ./configure --prefix=/usr/local/mysql --with-debug --with-low-memory

This doesn't affect the performance of MySQL, but has the side effect that you can't kill clients that are ``sleeping'' on a connection with mysqladmin kill or mysqladmin shutdown. Instead, the client will die when it issues its next command.

On some versions of AIX, linking with libbind.a makes getservbyname core dump. This is an AIX bug and should be reported to IBM.

For AIX 4.2.1 and gcc you have to do the following changes.

After configuring, edit `config.h' and `include/my_config.h' and change the line that says

#define HAVE_SNPRINTF 1

to

#undef HAVE_SNPRINTF

And finally, in `mysqld.cc' you need to add a prototype for initgoups.

#ifdef _AIX41
extern "C" int initgroups(const char *,int);
#endif

If you need to allocate a lot of memory to the mysqld process, it's not enough to just set 'ulimit -d unlimited'. You may also have to set in mysqld_safe something like:

export LDR_CNTRL='MAXDATA=0x80000000'

You can find more about using a lot of memory at: http://publib16.boulder.ibm.com/pseries/en_US/aixprggd/genprogc/lrg_prg_support.htm.

User Comments

Posted by Jean-Roch Lefort on Saturday August 9 2003, @11:46pm[Delete] [Edit]

I have encountered many problems with AIX SMP architecture compiling MySQL with Gnu C Compiler.
I spent more than one month studying this particular problems to come to the conclusion that if you need to run MySQL on a AIX SMP architecture, it is highly recommended to :

a) use the xlC compiler with the last patches applied.
b) make sure that the SMP library is present and that you link
the executable correctly to it ( if you install the SMP library on a monoprocessor machine, you WILL be able to generate a executable that WILL work on a SMP machine (no need to install the compiler on the target SMP machine if you have only one ).
c) run the built-in tests successfully before switching this to a production site.

Please feel free to ask me any question about that.

Add your own comment.